KNX Switch actuator, 2-gang
JUNG 2302.16REGHM

KNX Switch actuator, 2-gang

Product code: 2302.16REGHM
Switching of 110 ... 230 V AC or 24 V AC/DC electrical loads with floating contacts
Price (Excluding VAT)
£197.15

Description

Intended use

  • Switching of 110 ... 230 V AC or 24 V AC/DC electrical loads with floating contacts
  • Mounting on DIN rail according to EN 60715 in distribution boxes

Product characteristics

  • Manual switching of the relays is independent of the bus
  • Operation as NO or NC contacts
  • Logic operation and forcing function
  • Switching feedback (bus operation only)
  • Switch position display
  • Central switching function with collective feedback
  • Disabling function for each channel
  • Time functions: switch-on delay, switch-off delay, staircase lighting timer with pre-warning function
  • Integration into light scenes
  • Operating hours counter, configurable via bus
  • Input monitoring for cyclical updating with safety circuit
  • No additional power supply necessary

Technical Details

Specification

KNX medium: TP 256
Rated voltage KNX: DC 21 ... 32 V SELV
Connection, KNX: terminal
Power consumption KNX: typical 150 mW
Power loss: max. 2 W
Ambient temperature: −5 ... +45 °C
Storage/transport temperature: −25 ... +70 °C
Mounting width: 72 mm (4 rail units)

Connection, outputs
    Connection mode: screw terminals
    single wire: 1 x 0.5 ... 4 mm²
    stranded without ferrule: 1 x 0.5 ... 4 mm²
    stranded with ferrule: 1 x 0.5 ... 2.5 mm²

Switching outputs
Contact type: floating relay contacts (μ contact)
Switching voltage AC: AC 250 / 400 V
Switching current 230 V AC1: 16 A
Switching current 230 V AC3: 10 A
Switching current 400 V AC1: 10 A
Switching current 400 V AC3: 6 A
Fluorescent lamps: 10 AX
Ohmic load: 3680 W
Capacitive load: 10 A / 140 µF
Switching voltage DC: DC 12 ... 24 V
Switching current DC: 16 A
Min. switching current: 100 mA
Switch-on current 150 µs: 400 A
Switch-on current 600 µs: 200 A

Lamp loads
Incandescent lamps: 2500 W
HV halogen lamps: 2500 W

LV halogen lamps with
    inductive transformers: 1200 VA
    electronic transformers: 1500 W

Fluorescent lamps T5/T8
    non-compensated: 2500 W
    parallel compensated: 1300 W / 140 µF
    lead-lag circuit: 2300 W / 140 µF

Compact fluorescent lamps
    non-compensated: 2500 W
    parallel compensated: 1300 W / 140 µF

Mercury vapour lamps
    non-compensated: 2000 W
    parallel compensated: 2000 W / 140 µF

Approvals: VDE

Properties

Properties

Technology KNX
Brand JUNG
Mounting DIN Rail
Outputs 2