KAISER
9459-02/10
Fire protection conduit sealing system RS 90 (bag of 10)
Product code:
9459-02/10
Pipe and fire-retardant systems for safe closure of passages and entrances in fire-protection walls.
Description
Pipe and fire-retardant systems for safe closure of passages and entrances in fire-protection walls. The certified retardants are quick and easy to install and can even be superimposed on cables and pipes retrospectively.
- For fire-protection walls EI 30 - EI 90
- For wall entries and feed-throughs
- Without use of fire-protection foam or putty
- Made of intumescent material
- Automatic room separation of the installation opening
- Unlimited building material shelf life
- Secure, visible, certified fire sealings
- For wall feed-throughs and entries
- Without filling and smoothing
- Automatic sealing of the joints
- For cables from Ø 5 - 15 mm
- For conduits M16 - M25
Technical Details
Specification
- Installation opening (cavity wall): 35 mm
- Installation opening (masonry): 32 mm
- For conduits: M16 - M25
- Min. wall thickness: 100 mm
- ETA approval: applied for
- VKF approval: 21044
Properties
Properties
Technology | Accessory |
Brand | KAISER |