Smart Connect KNX Vaillant
Description
The ise smart connect KNX Vaillant allows you to implement innovative solutions for your intelligent house:
You won't be at home for a longer period of time. KNX enables you to perform an occupied-home simulation today, allowing you to conveniently activate the alarm system. With the ise smart connect KNX Vaillant, you can now also switch your heating system to "standby mode". This allows you to reduce the room temperature setpoint values in all rooms (if desired) and minimise heating.
Do you want to be able to react to short-term changes in use quickly and easily (longer than usual periods of absence, events, parties, etc.)? With the ise smart connect KNX Vaillant, the times and setpoint values for heating and hot water can be changed temporarily, or you can adapt ventilation control (especially through ventilation boost) to your current requirements.
In combination with the Vaillant VRC 700 (UK)/multiMATIC 700 (EU) heating regulator, the ise smart connect KNX Vaillant and the ise eBUS adapter, you can now integrate the heating system, ventilation system and/or the yield and consumption values in building scenarios, visualisation and facility management systems.
Features:
- Control of operation mode and temperature setpoint values for up to three heating zones
- Control of operation mode and temperature setpoint value for hot water supply
- Control of ventilation system operation mode
- System information like service mode, error messages, date and time, outside temperature, system status
- Yield values of solar systems and heat pumps
- Consumption values for hot water supply and heating (electricity, gas)
- Only for systems with multiMATIC/VRC heating regulator
- For the latest version of ETS4 or ETS5
Technical Details
Specification
ise smart connect KNX Vaillant
- Operating voltage: DC24 to 30V
- Current Consumption: 125mA at 24VDC
- IP communication: Ethernet 10/100 BaseT (10/100 Mbit/s)
- Supported protocols: ARP, ICMP, IGMP, DHCP, AutoIP, UDP/IP, KNXnet/IP as per KNX System Specification: Core, Device Management
- Connections: 1 x RJ45 socket for IP connection, 1 x USB Type A
- MicroSD Card: Up to 32GB microSDHC
ise eBUS Adaptor
- Operating voltage: supply via Bus
- eBus Connection: Connection Terminal
- USB Connection: 1 x mini USB B (used to connect to Smart connect KNX Vaillant
- eBUS power Consumption: .1W at 24VDC
- USB power Consumption: 0.05W at 5VDC
- IP communication: Ethernet 10/100 BaseT (10/100 Mbit/s)
Properties
Properties
Technology | KNX |
Brand | ISE |
Mounting | DIN Rail |
Operating voltage | 24VDC |
IP rating | IP20 |
Mounting Width | 3MW |